JFD's Kinergetics habitat conditioning unit HCU-3 is a cost effective method of controlling temperature, humidity and CO2 within saturation diving chambers.
Designed to operate with the heating and chilling skid (HCS-1), the HCU-3 is rated to operate at depths down to 300msw and available in two options.
The HCU-3/4, which can accommodate up to four divers and the HCU-3/6, which accommodates up to six.
Further Information
General |
|
Depth rating |
300 msw |
Diver rating |
HCU 3/4 - 4 divers HCU 3/6 - 6 divers |
CO2 absorbent | 6.3kg per canister |
Power drive |
24V Ac or DC, 7 amps |
Mass |
60 kg |
Pipe Connections | |
Dehumidification water supply | 1/2" NPT female |
Reheat water supply |
3/4" NPT female |
Electrical connection | Single pin, 2 contact |