JFD's hyperbaric conditioning unit - external regeneration (HCU-ER) conditions the internal atmosphere of a saturation diving complex to maintain a habitable environment.

The external regeneration system provides increased diver comfort by having the system placed outside of the living chambers.

The HCU-ER HCU100 series offers uninterrupted operation through its twin scrubber design, enabling the change out of chemical absorbent whilst maintaining habitat conditioning capability.

Further Information

The HCU-ER HCU100 series extracts gas from the chamber into the active scrubber, injecting additional moisture to improve scrubbing capacity. The gas passes through the chemical absorbent which retains any CO2 present in the gas.

Gas is then transferred to the dehumidifier where it passes over a cold water coil. This coil has the effect of lowering the gas to a temperature below its dew point; reducing relative humidity and enabling the collection of condensation in the dehumidifier sump.

The 3-stage blower then accelerates the gas into the heater where a hot water coil increases the gas temperature. The fully reconditioned gas is then circulated back into the chamber.

Local control via HMI allows the operator to view at a glance chamber temperature, humidity, blower speed and alarms; as well as establish set points for these criteria and run system tests. Essential to the operation of the HCU-ER is the supply of 440VAC, 3~, 60Hz, which is transformed and rectified to 24VDC by the integral HCU transformer.

Design depth

350 msw

 

PV design code

PD5500:2006

 

Construction

316L stainless steel

 

Max no of occupants supported

6 compressed divers

 

Min operating depth

0 msw

 

Max operating depth

350 msw

 

Working pressure

35 bar

 

Test pressure

46 bar

 

Design temperature

-20ºC to 80ºC
3” ANSI B16.5 class
300 RF flange
 
Gas outlet 3” ANSI B16.5 class
300 RF flange
 
Gas reclaim 1/2” FNPT  
Hot water inlet 3/4” FNPT  
Hot water outlet 3/4” FNPT  
Cold water inlet 3/4” FNPT  
Cold water outlet 3/4” FNPT  
Water injection 1/2” FNPT  

Drain line

1/2” FNPT  

 

CO2 scrubber

Capacity

17.6 kg (8.8 kg per basket)

 

 

3-stage variable speed blower

Max Rpm

7000 Rpm

 

Gas flow

2.8 m3/min-1  

 

Dehumidifier

Cooling capacity

Max 10 kW
Water removal 780 ml/hr at 50% RH

 

Heater

Heating capacity

Max 10 kW

 

Controls

Temperature control

22ºC to 32ºC +/- 1ºC
(+/- 0.5ºC tgt max var)
 

Humidity control

40% to 65% RH +/- 5%  

 

Dimensions HCU100BA

Length

2000 mm

Width

1200 mm

Height

1850 mm

Weight  1400 kg

Hot water requirement

Min flow

20 Lpm

Min temp

60ºC

Min pressure

4 bar

Cold water requirement

Min flow

20 Lpm

Min temp 2ºC
Min pressure

4 bar

Fresh/potable water requirement 

Min flow

5Lpm with 10μm filtration

Min temp

Ambient

Min pressure

45 bar

Power requirement

Power requirement

440VAC, 3~ , 60Hz

Document Document type Download

Hyperbaric conditioning unit - external regeneration HCU-ER

Datasheet KI-MDS-567 R1

Hyperbaric conditioning unit - external regeneration HCU-ER - single scrubber pot, 350 msw (HCU100BA series)

Operation and maintenance HCU100-OM-6739 R0
James Fisher is a global supplier of trusted engineering services across the industries we serve, with an unrivalled ability to develop innovative solutions that meet the constantly developing needs of our customers operating in challenging environments.
Contact us for more information