JFD's Divex chamber conditioning unit CCU-07 has been designed for use in hyperbaric environments, specifically focused on heating and atmosphere sweetening.
It is rated to depths of 500 MSW and forms part of the extensive range of Divex hyperbaric environment conditioning equipment, both air and heliox.
The CCU-07 has been specifically designed for heating and atmosphere sweetening (odour removal), as well as for temperature and humidity control.
Further Information
Components contained in the chamber conditioning units include:
- Coil assembly: heating and cooling coils fitted to common end plates forming a single coil assembly, mounted inside the heat exchanger box. Chamber atmosphere first passes through the cooling coil and then through the heating coil.
- Heat exchanger box: encloses heat exchanger assembly. Mounted on to plenum or duct assembly.
- Plenum or air duct assembly: positioned between the heat exchanger assembly and the blower assembly and includes mounting brackets.
- Blower assembly: produces the flow of breathing gas and includes electric motor.
- Carbon filter assembly: provided with fine wire mesh screen in top and bottom halves of assembly to house activated carbon granules. Is secured on to the front of the heat exchanger box on the CCU-07.
*These are calculated values that need to be verified by testing in hyperbaric environments.
Electrical requirements | 24 VDC, ± 2A |
Air volume moved | Up to 10m3/min |
Heating capacity* (with both coils connected in series) |
5000 W @ 100 msw 9600 W @ 300 msw Heliox |
Heating liquid requirements | 0.2 litres/min |
Coil construction | 25 litres |
Housing and blower assembly | Gr. 316 stainless steel |
Heating fluid ports | 1/2" NPT (F) |
Coil external pressure test | 65 bar (hydro) |
Assembly leak test | 50 bar (helium) |
Required mounting | Can be mounted in any orientation |
Suggested atmosphere | Activated carbon granules |
Sweetener for carbon filter | Divex p/n.CM001 |
Document | Document type | Download |
Kinergetics chamber conditioning unit CCU-07 | Datasheet | KI-MDS-571 R1 |
Item | Order code |
Chamber conditioning unit CCU-07, standard | KI40054 |
Chamber conditioning unit CCU-07, Lloyds approved | KI40054LYD |
Chamber conditioning unit CCU-07, DNV approved | KI40054DNV |
Chamber conditioning unit CCU-07, ABS approved | KI40054ABS |

Contact us for more information