The JFD interlock is designed to prevent the doors of medical, equipment, or transfer locks being opened whilst under pressure.

This interlock is very simple to operate. As the chamber is pressurised, the interlock mechanically locks the bolt in the extended position. The interlock bolt cannot be retracted until the chamber pressure is less than 1psi.

When the bolt is in the retracted position the gas supply to the chamber is isolated and the chamber cannot be pressurised.

When the bolt is retracted the chamber is vented through the interlock vent ports, this ensures that the chamber cannot be pressurised from another source. This facility also allows the interlock to be used in a vent only configuration, in which case port B would be plugged.

Further Information

Item Order Code
Interlock DC0300AA
Spares kit for interlock DC0300202
Interlock DNV approved DC0300DA
Interlock Lloyds approved DC0300LA

Design and operational notes

Interlock bolt cannot be retracted with port pressure above 1psi.

Pressure ratings

Maximum working pressure 45 bar
Design pressure 49.5 bar
Hydrostatic test pressure 68 bar
Design temperature -20oC to +50oC

Bolt and bolt stroke can be any practical length. (By changing interlock bolt only). Interlock can lock in any attitude.

James Fisher is a global supplier of trusted engineering services across the industries we serve, with an unrivalled ability to develop innovative solutions that meet the constantly developing needs of our customers operating in challenging environments.