The SE850 Hyperbaric Flame Detector is specifically designed to be used within the harsh environment of saturation diving systems and is suitable for depths up to 500 msw.

It operates by detecting the ultraviolet radiation emitted by a flame, while not being sensitive to visible light. Detection is signalled by a front-mounted red LED, and by a set of normally-closed relay contacts. The detector is housed within an aluminium pressure housing, which protects the internal electronics from the pressurised environment typically found within a saturation diving chamber.

The SE850 Hyperbaric Flame Detector is type approved for use in saturation diving systems by both Lloyd's Register and DNV-GL.

LR Type Approval Certificate: 17/90004
DNV-GL Type Approval Certificate: TAA000017X

Further Information

Item Order code
Hyperbaric flame detector with 10m cable tall SE850
Working pressure 50 bar
Depth rating 500 msw
Dimensions Length 220mm x 66mm dia
Weight 1.6kg
Supply voltage 24 Vdc (+/-20%)
Current consumption 0.1 A
Relay contacts max. load 60 Vdc / 3 A
Operating temperature 0-55C
Detection wavelength 185 to 260 nm
Device sensitivity Class 3 (12m)
Detection angle 30 degrees from optical centre

 

Electrical Connections

1 +Vin (power supply positive)
2 -Vin (power supply negative)
3 Not used
4 Not used
5 Not used
6 RC+ (positive terminal of normally closed contacts)
7 RC- (negative terminal of normally closed contacts)
Document Document type Download
SE850 Hyperbaric Flame Detector Datasheet

SE-MDS-6609-R2

James Fisher is a global supplier of trusted engineering services across the industries we serve, with an unrivalled ability to develop innovative solutions that meet the constantly developing needs of our customers operating in challenging environments.
Contact us for more information