The Divex HeliCom™ dive control helium speech unscrambler is designed for helium speech communication with three divers and the bell environment.

A front panel loudspeaker allows the diver's speech to be audible to the diving supervisor, independently of his headset, in all modes of operation. An on/off switch allows the loudspeaker to be switched off as required.

Further Information

General

Power 110/230 VAC 50/60 Hz  
Fuse rating 2 Amp  
Power amplifiers 1 per channel  
Power output 10 watts per channel  
Frequency response

300 Hz to 12kJz

 
Input impedance

600 ohms, transformer isolated

 
DSP unscrambler

Common to all 3 diver channels

 
Voice correction range

0m to 500m (0 ft to 1,640 ft)

 
Audio recording Recording level control with VU display  

Connector

Audio connectors (diver 1, diver 2, diver 3 and bellman)  5 pole panel mount XLR socket, P/No EM3617, rear panel  
Remote PTT 5 pole panel mount XLR socket, P/No EM3617, rear panel  
Supervisor headset ¼” headset socket, front panel  
Recording output BNC bulkhead socket, rear panel  

Dimensions

Height - 19” sub-rack H 4U (177.8 mm)
Width - 19” sub-rack W 84 HP (426.7 mm)
Depth

355 mm

Weight

7.5 kg

Environmental

Operating temperatures -10oC to +40oC
Storage temperatures -20oC to +60oC
Type Document Download
Datasheet HeliCom™ dive control helium speech unscrambler CO-MDS-490 R01
Drawing HeliCom™ dive control helium speech unscramble c/w R-R CO36325S1 R3
Manual HeliCom™ dive control helium speech unscramble operation and maintenance (Part number: CO363AY) CO-OM-248 R6
Item Order code
HeliCom™ dive control helium speech unscrambler CO363AY
James Fisher is a global supplier of trusted engineering services across the industries we serve, with an unrivalled ability to develop innovative solutions that meet the constantly developing needs of our customers operating in challenging environments.